Quality tablet punches and dies manufacturer factory: Usually, the movement or activity of personnel should be reduced as much as possible in the laboratory, and the door of the clean room should be closed or automatic door closers should be installed to keep it closed. Stop use immediately when the cleanliness does not meet the requirements: When the cleanliness does not meet the requirements, it should be stopped immediately, find the cause, thoroughly clean, must be verified by the cleanliness and meet the requirements, and then use again, and record the situation in the aseptic room use register, regular archival storage. Guidance and supervision of incoming foreign personnel or maintenance personnel: non-microbial room inspection personnel shall not enter the clean room (aseptic room), and foreign personnel or maintenance personnel who must enter shall be guided and supervised. Discover additional information on pill stamp press.
The internal structure should reduce the use of squares and try to use polished circles and slopes as much as possible, which is beneficial for the transfer of internal items and avoids obstacles. Ensure the sealing of the machine and isolate the working or manufacturing area from the outside environment. Isolation covers can be set up. In the selection of materials. The characteristics of the drug should be considered to prevent chemical reactions that may affect the drug. The material in direct contact with the material is usually higher grade than the external material, usually 304 stainless steel or 316 stainless steel. Corrosion resistance, high and low temperature resistance should also be considered, and sometimes titanium alloys are also used.
V-type mixer series products are high-efficiency asymmetric mixers, which are applicable to the mixing of powder particles with good material fluidity and small physical property differences, as well as the mixing of materials with low mixing degree and short mixing time. Since the flow of materials in the V-type mixing container is stable and will not damage the original shape of materials, the V-type mixer is also applicable to the mixing of granular materials that are easy to break and wear, or fine powder particles, blocks. It is widely used in pharmaceutical, chemical, food and other industries.
In summary, maintaining the right humidity level in clean rooms is vital for ensuring their effectiveness and longevity. By understanding the normal humidity range for clean rooms (between 40% and 60% RH) and implementing proper cleanroom humidity control techniques such as using a dehumidifier, hygrometer, proper ventilation, and controlling water sources, professionals can help create a controlled environment that promotes optimal performance and safety.
Mainly control the pollution of air dust particles and organisms (bacteria) to working objects, and maintain a negative pressure with the atmosphere inside. Pharma cleanroom project It is suitable for precision machinery industry, electronics industry, aerospace industry, high-purity chemical industry, atomic energy industry, optomagnetic product industry, LCD, computer hard disk; pharmaceutical industry, hospital, operating room, sterile ward, food, cosmetics, beverage products Animal laboratory, physical and chemical laboratory, blood station, etc. More cases check our cleanroom project page.
For the unidirectional flow (laminar flow) clean room, the air supply volume is determined by the product of the average wind speed of the room section and the cross-sectional area, in which the measured section of the vertical unidirectional flow (laminar flow) clean room is the horizontal section 0.8m away from the ground; The horizontal unidirectional flow (laminar flow) clean room takes a vertical section 0.5m away from the air supply surface. The spacing of measuring points on the section shall not be greater than 2m, and the number of measuring points shall not be less than 10, which shall be evenly arranged. Hot bulb anemometer for instrument.
High quality pharma machinery manufacturer: Generally, the air flow distribution point on the surface of the operating table or production equipment should be located at 2/3 of the distance between the clean room space and the partition wall, so that when the operator is working, the air flow can flow from the inside of the process area to the operation area, and the The dust is taken away; if the distribution point is arranged in front of the process area, it will become an improper airflow distribution. At this time, most of the air flow will flow to the process area, and the dust caused by the operator’s operation will be brought to the back of the equipment. As a result, the platform will be polluted, and the yield rate is bound to decrease.
Clean shed, also known as clean work shed (dust-free shed, purification shed, operating table, etc.), is a small space surrounded by anti-static mesh curtains or plexiglass in the clean room, and HEPA and FFU air supply units are used above. It is composed of a space with a higher purification level than the clean room, and the clean room can be equipped with purification equipment such as air shower room and transfer window.
A clean room is defined as a room with air filtration, distribution, optimization, construction materials and devices, where specific regular operating procedures are used to control airborne particulate concentrations to achieve an appropriate level of particulate cleanliness. A clean room refers to the removal of particulates, harmful air, bacteria and other pollutants in the air within a certain space, and the indoor temperature, cleanliness, indoor pressure, airflow speed and airflow distribution, noise vibration and lighting, static electricity. A specially designed room that is controlled within a certain demand range. Read even more details at https://www.sz-pharma.com/.
Suzhou Pharma provides a wide range of cleanroom supplies that will be used to clean and disinfect surfaces such as floors, walls, ceilings and isolators; including cleanroom wipers, sticky mat, brush, cap, clothes, booth, label, shoes, sleeves. These products usually have low dust, anti-static and other features, and widely used in pharmaceutical, medical, chemical, electronic industries and other dust-free workshop. Suzhou Pharma offers doors systems adapted to your production prozess, taking account of the space available and how frequently the clean rooms are. During the engineering process we are considering the most economical system. the door systems are as revolving doors, swing door, sliding door and rolling gate available. Fulfilling the most exacting demands of clean room classes, the door panel can be set under reduced pressure. This reduces the particle emission.