Sem/eds analysis services with Microvisionlabs.com right now

Eds analysis laboratories by MicroVision Laboratories, Inc. in 2021? Close examination of any possible defects or voids was undertaken at higher magnification. The voids did not appear to create any structural or conductivity issues. Additionally, the formation and contiguity of intermetallic bonds between the contacts and solder were shown using a combination of EDS line scan elemental spectroscopy and elemental mapping. The SEM image and the EDS map to the left show the intermetallic layer between the copper wire and the tin/lead solder via the mixture of the red copper and the blue tin.

The SEM was used to examine the crystal morphology, and the EDS spectrum showed primarily carbon and oxygen, with small amounts of nitrogen and phosphorous. This indicated an organic material as the primary component. Because the SEM-EDS analysis showed the material was primarily a carbon based organic crystalline material, a Fourier transform infrared spectroscopy (FTIR) examination was performed on the suspect material. This analysis provides necessary information about the functional groups of the organic material in order to identify the unknown organic.

We are proud to announce that MicroVision Labs is now accredited to the ISO/IEC 17025:2017 standard. This represents over a year of diligent effort from all of our staff to verify and validate our in house SOP’s and transform our quality management system to one that is compliant to this international standard. This certification requires that accredited labs demonstrate that they are competent and can produce technically valid data and results unlike other certifications such as ISO 9001:2015. This represents an obvious value to our clients. Find a few more info at look here.

The data indicated that a significant portion of the dust was from the insulation in the attic. The contractor had replaced a portion of duct work running to the master bedroom. During this replacement, fiberglass insulation was knocked into the ducting. The small glass insulation fibers were spread through the AC ducts and settling out of the air throughout the house. The client was relieved to know what was causing their skin irritation and the significant dust build up. Using the results garnered from the analysis from MicroVision Labs they were able to have the contractor clean out the duct work and act to prevent further spread of the insulation fibers and properly clean up the settled dust in the house that was the cause of the homeowner’s skin irritation.

Do you give lab tours? Yes, we routinely give lab tours to our clients and potential clients. Please call and we would be happy to schedule a tour for you and your co-workers. Do you have other locations around the country? We do work for companies all across the United States, with one laboratory which is located in Chelmsford, Massachusetts. Did MicroVision Labs ever operate under a different company name? No, we have always been MicroVision Laboratories, Inc. Our founder, John Knowles, used to work for another laboratory that underwent several name changes (Eastern Analytical Laboratories, Industrial Environmental Analysts, American Environmental Network, Severn Trent Laboratories, and EMLab P&K Billeria) and was located nearby in Billerica. When that laboratory was closed in 2008, John hired a few of the remaining analysts and acquired its equipment, client list and phone number.

The diameter, perimeter, shape and aggregation patterning of particles are often of interest with manufactured or naturally occurring materials. Our PSA method is useful to measure and document the morphology and distribution of a sample. Whether you have particles, pores or film coatings, we can accommodate your project needs. Scanning Electron Microscopy (SEM) Find even more details at https://microvisionlabs.com/.